Graphic Command; Esc+G Graphic Print - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

11 Graphic Command

Graphic
11.1
11.1

ESC+G Graphic Print

Graphic Print
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the print of graphic.
[Format]
<G>abbbcccn~n
●Parameter
a [Data specification by HEX and BIN]
H: Hex data
Divide 8 bits data into 4 bits and output it as hex code corresponding to ASCII.
B: Binary data Output 8 bits data as one font of data all at once.
b [Specification of crosswise graphic area per byte] = Valid range: Refer to the table below
c [Specification of lengthwise graphic area per byte] = Valid range: Refer to the table below
n [Graphic data]
[Coding Example 1] [H: HEX data] is specified for [Data specification by HEX and BIN]
<A>
<V>50<H>50
<G>H001001<46463831383138313831383138314646>16
<Q>1
<Z>
[Coding Example 2] [B: Binary data] is specified as Data specification by HEX and BIN]
[□] is printed with the below specification.
<A>
<V>50<H>50
<G>B001001<FF818181818181FF>16
<Q>1
<Z>
[Supplementary Explanation]
1. Specification of [B] has longer program description than that of specification [H]; however, transfer data length is 50
percent shorter. This could be advantage in data capacity.
2. Specification of Rotation <%> and Enlargement <L> are available.
3. <L> command should be placed just before <G> command.
4. When using rotation <%> and enlargement <L> commands at the same time, specify <%> command before <L>.
5. The crosswise maximum byte and lengthwise maximum byte are specified in the table below, however, it is possible
to specify up to 999 bytes to have compatibility with the old model.
The graphic data less than 2,937,600 bytes can be printed.
6. The calculation of graphic data size is [crosswise maximum byte x lengthwise maximum byte x 8].
[Valid Range]
Model
203 dpi
CL4NX
305 dpt
609 dpi
203 dpi
CL6NX
305 dpt
(*1) Valid range for "Standard" in "Head Base Position" setting.
(*2) Valid range for "Left-justify" in "Head Base Position" setting.
Refer to the operator manual for further information of the setting.
G
<47>
16
[□] is printed with the below specification.
Crosswise max. bytes
104
156
312
152 (*1)
167 (*2)
248 (*1)
251 (*2)
Parameter
abbbcccn~n
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Lengthwise max. bytes
400
600
999
400
600
246
ESC+G

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents