SATO CL4NX Programming Reference Manual page 342

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

<RU>,01 return sequence (
<RU>,01 *1
Return based on [DC2]PK
<IP0>e:h,epc:E0123456789ABCDEF0123456;
Write command
[DC2]PK
*1.Most common commands such as <A>, <Z> are not described in the above diagram.
*2.The content of the return EPC/TID is an example. The actual value varies depending on the tag.
[Supplemental explanation]
1.Keep the EPC/TID data to be returned within 256 characters.
2.The printer operation corresponding to the <IP0> command is performed in the order of writing the data to the tag,
and then performing EPC/TID reading.
for a Gen2 tag having the TID of
Host
334
E0123456789ABCDEF0123456)
Printer
The settings of return based on
[DC2]PK are retained
Enabled until power is turned OFF
Acquire
TID
immediately
successful write, and store it in the
memory with the success status.
Return
the
write
status
success) and TID data
[STX] 25,1,N,ID:E200680612345678
[CR][LF][ETX]
*2
after
(write