SATO CL4NX Programming Reference Manual page 325

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Conventional format
The format for Gen2(Class1Generation2) tag only.
Use the standard format for the tag from the IC chip manufacturer having an EPC area of more than 96 bits.
<IP0>e: Write these parameters after specifying " * ".
Conventional format: One-character parameter identifier (SSCC96 code conversion / SGTIN96 code conversion /
free mapping)
EPC data parameter
d:
EPC data
SSCC96/SGTIN96 conversion parameter
f:
filter value
c:
company prefix
s:
serial reference
t:
item reference
n:
serial number
Feed control parameters (can be omitted)
g:
Feed without printing
Specify the EPC data. The restrictions on the number of digits based on each EPC
encoding type are as follows:
When
SSCC96
code
A 17-digit decimal number sequence in which the company
conversion is specified
prefix and serial reference are joined together
<IP0>e:a,..
A 13-digit decimal number sequence in which the company
When SGTIN96 code
prefix and item reference are joined together
conversion is specified
<IP0>e:c,..
A hexadecimal string containing 24 or less number of digits in
multiples of four, which is written without conversion in the
When free mapping is
EPC area. Use the standard format in an application
specified
exceeding 24 digits (96 bits).
<IP0>e:z,..
You may also use the space, tab, line feed in data separator,
but these codes will be skipped.
Refer to the filter value and the filter value standard table described later.
Number of digits of the company prefix
A number from 6 to 12. Number of digits of the company prefix in the first
half of the data specified in the d parameter.
Number of digits of Serial reference (only when selecting SSCC96)
Number of digits of the serial reference in the latter half of the data
specified in the d parameter. Specify a number from 5 to 11, so that when
combined with c, the resultant value is 17.
Number of digits of Item reference (only when selecting SGTIN96)
Specify a number from 1 to 7, so that when combined with c, the resultant
value is 13.
Serial number 12 digits (fixed) (only when selecting SGTIN96)
Specify 274877906943 or a smaller number.
Usually, for RFID write item without print data, only writing of RFID data is
performed, and the label is not fed.
(Except for cases where the tag offset is set to other than default)
When "1" is specified in this parameter, the label is fed even if the item
does not contain print data.
When "0" is specified for this parameter, the label is not fed for the item
without print data, and the operation is the same as when g: is not
specified.