10.15 2D code
10.15
ESC+FX Datamatrix (ECC200) Sequential
DataMatrix (ECC200)
Number(Compatible Commands)
Sequential Number(Compatible Commands)
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying sequential number for DataMatrix.
[Format] (Sequential number part)
<FX>aaabcccdddeee
●Parameter
a [Number of duplication to print]
b [Flag of increase and decrease]
c [Number of increase and decrease]
d [Specification of digit position]
e [Number of digit]
[Coding Example] Number of duplication to print: 001, Flag of increase and decrease: +
Number of increase and decrease: 001, Digit position: 005, Number of digit: 003
<A>
<V>100<H>200
<FX>001+001005003
<BX>01100202000000001
<DC>00006000
<Q>2
<Z>
[Supplementary Explanation]
This command is for existing models. Using DataMatrix(ECC200) command <2D50> is recommended.
FX
Parameter
<46>
<58>
aaabcccdddeee
16
16
The set parameter is maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
Valid Range
=
+
-
=
Valid Range
=
Valid Range
=
Valid Range
243
ESC+FX
:
001 to 999
:
Increment
:
Decrement
:
001 to 999
:
001 to 999
:
001 to 999

Advertisement