[Sample of status reply 4](format set to ASCII)
When there is not an RFID tag or when an RFID tag is bad.
Command
[DC2]PJ,H1,AS
Status reply [STX]2,06[ETX]
Command
[DC2]PJ,H1,H3,AS
Status reply [STX]2,06[ETX]
Command
[DC2]PJ,HA,AS
Status reply [STX]2,06[ETX]
[Supplemental explanation]
1. This command cannot be used in combination with commands other than <A> and <Z>.
2. When the issue operation of the printer only is a continuous, cutter(motion 1), and dispenser(motion 1), this
command can be used.
Not available for tear-off mode, cutter(motion 2), dispenser(motion 2).
3. This command will not work properly when tag offset is set anywhere other than default position.
4. Because this command cannot be received while printing it, information cannot be acquired in "Sequential number"
and "Print Quantity" piece is specified.
5. After this command is transmitted, it will take about five seconds by the time all the sending return status is sent back
by the host. Tag information is not correctly sent back when the port is cut before all the sending return status is sent
back by the host, data other than the sending return status format are sent back, and operate it, please after
selecting data.
6. Please do not transmit other commands and data until all the status of the defined size is received by the host after
transmitting this command.
7. Refer to the following chart if you want to specify the alphabet "A" in ASCII/HEX data formats.
Mode
Data
Code
8. For my-d tag, custom mode is read by default. However, in order to force read with ISO mode, specify "AI" and "HI"
as an option. "AI" stands for ASCII format and "HI" stands for HEX format data reply.
9. Only my-d tags can be specified for options "AI" and "HI". If you specify other than my-d, the options will be identified
as "AS" and "HX".
10. If the printer is a low power consumption mode is enabled, until it wakes up will return a "NAK".
Host
Inlet type(RFID tag none/reading error)
Inlet type(RFID tag none/reading error)
Inlet type(RFID tag none/reading error)
ASCII
HEX
'A'
"41"
41H
34H,31H
DC2 + PJ,aa(,aa)(,aa),bb
STX + aa,bb, + cc:d...d,e...e +ETX
Or, STX + aa,bb,+ cc:e...e +ETX