Esc+Rm Mirror Image - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

7.18 Modification
7.18
ESC+RM
Mirror Image
Mirror Image
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Performing mirror rotation of print data.
[Format]
<RM>aaaa, bbbbb
●Parameter
a[Horizontal range of mirror rotation specification]
b[Vertical range of mirror rotation specification]
[Coding Example 1]
When the range of mirror rotation is specified:
<A>
<H>100<V>200<XS>12345
<H>100<V>200<RM>0200,0080
<Q>1
<Z>
[Coding Example 2]
When the range of mirror rotation is not specified:
<A>
<H>100<V>200<XS>12345
<RM>
<Z>
[Supplementary Explanation]
1. When the parameter "aaaa" and "bbbbb" are not specified, all print data specified prior to this command will be
rotated.
2. Data outside of print area will not rotate.
3. If specifying this command for the item that does not contain print data, the command error will occur.
4. This command cannot be used in combination with the commands that associated with reedition of print data. Refer
to the invalid command for the list below. When invalid commands are specified, printing may not be correct.
5. This command cannot be used in combination with some registration commands. Refer to the invalid command for
the list below. When the command that cannot use in combination with is specified, print result is not guaranteed.
6. This command cannot be used together with some of the modification commands. Refer to the invalid command for
the list below. When the command that cannot use in combination with is specified, print result is not guaranteed.
7. This command print the mirror image of the print data put before the mirror rotation command is specified. The data
after the command don't rotate. Note that specifying this command several times results rotating the data several
times.
8. When the mirror image is applied for the barcode, reading of the barcode and the head damage check are not
guaranteed.
9. When executing the mirror image, the head damage check will be performed for all the areas where rotated.
[Valid Range for start position of mirroring]
Model
203 dpi
CL4NX
305 dpi
609dpi
203 dpi
CL6NX
305 dpi
(*1) Valid range for "Standard" in "Head Base Position" setting.
(*2) Valid range for "Left-justify" in "Head Base Position" setting.
Refer to the operator manual for further information of the setting.
RM
Parameter
<52>
<4D>
aaaa,bbbbb
16
16
Horizontal start position of mirror rotation
specification
1 to 832
1 to 1248
1 to 2498
1 to 1216 (*1)
1 to 1340 (*2)
1 to 1984 (*1)
1 to 2010 (*2)
36
ESC+RM
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
= Valid range: Refer to the table below.
= Valid range: Refer to the table below.
Valid Range (dots)
Vertical start position of mirror
rotation specification
1 to 20000
1 to 18000
1 to 9600
1 to 20000
1 to 18000

Advertisement