Esc+Eu Composite Symbol - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

9.13 Barcode
9.13

ESC+EU Composite symbol

Composite Symbol
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the composite symbol of EAN/UCC.
[Format 1]
<EU>aabbccn~n
●Parameter
a [Type of composite symbol]
b [Narrow bar]
c [Segment width
n [Print data]
Maximum number of digit for 1D barcode data
GS1 DataBar Composite (CC-A/CC-B)
GS1 DataBar Truncated Composite (CC-A/CC-B)
GS1 DataBar Stacked Composite (CC-A/CC-B)
GS1 DataBar Stacked Omni-Directional (CC-A/CC-B)
GS1 DataBar Limited Composite (CC-A/CC-B)
GS1 DataBar Expanded Composite (CC-A/CC-B)
/ GS1 DataBar Expanded Stacked (CC-A/CC-B)
UPC-A Composite (CC-A/CC-B)
UPC-E Composite (CC-A/CC-B)
Specify with "XX00000XXX" (X: variable) format.
EAN13 Composite (CC-A/CC-B)
EAN8 Composite (CC-A/CC-B)
- Check digit is automatically calculated and added.
- To specify the print of composite symbol, delimit one-dimensional data and two-dimensional data with '|'(7Ch).
Data = One-dimensional data | Two-dimensional data
-Data of GS1 DataBar Composite (CC-A/CC-B) are needed to be specified between the 1st and 16
DataBar Expanded Composite (CC-A/CC-B) data.
-GS1 DataBar Expanded Composite (CC-A/CC-B) can contain GS1 DataBar Composite (CC-A/CC-B) data and 74
digit of numeric character and 41 digits of alphabet.
(When numeric characters and alphabets are mixed, GS1 DataBar Composite (CC-A/CC-B) data and 41 digit
characters can be specified.
-When specified data don't reach the maximum digits, blank is filled by zero.
-2D data can contain up to 338 digits, but it varies by the type of Barcode.
-Barcode may stick out of the label depending on data and the number of digit, and scanner cannot read it. Adjust
print data beforehand so that the barcode can fit to the label.
EU
Parameter
<45>
<55>
aaabbn~n
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
01 :GS1 DataBar Composite (CC-A/CC-B)
02 : GS1 DataBar Truncated Composite (CC-A/CC-B)
03 : GS1 DataBar Stacked Composite (CC-A/CC-B)
04 : GS1 DataBar Stacked Omni-Directional (CC-A/CC-B)
05 : GS1 DataBar Limited Composite (CC-A/CC-B)
06 : GS1 DataBar Expanded Composite(CC-A/CC/B)
/ GS1 DataBar Expanded Stacked (CC-A/CC-B)
07 : UPC-A Composite (CC-A/CC-B)
08 : UPC-E Composite (CC-A/CC-B)
09 : EAN13 Composite (CC-A/CC-B)
10 : EAN8 Composite (CC-A/CC-B)
=
01 ~ 12 dots
=
02 ~ 22 (Even number only)
* Only GS1 DataBar Expanded Composite (CC-A/CC-B) are supported
=
Data
151
ESC+EU
13 digits
13 digits
13 digits
13 digits
13 digits
74 digits
11 digits
Fixed 10 digits
12 digits
7 digits
th
digit of GS1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents