my-d ISO operation(omissible)
Valid range:0~1
Specify 1 to access my-d using ISO-15693 standard. My-d custom command is used to access my-d if this field is
not specified or is 0.
iso:
Note:
Specify 1 to this field so that it can be used with ISO when you write to my-d light SRF550V01P since this chip
does not support custom commands.
Parameters from here can be specified in any order.
Parameters related to specifying block to start writing (omissible)
wsb:
Specify block to start writing
(former Ws:)
Mapping table of inlet type and number of blocks, and total capacity
Inlet Type
ICODE SLI
ICODE(a=2)
ICODE SLIX
ICODE SLIX-S
Tag-it HF-I Plus
Tag-it(a=3)
Tag-it HF-I Pro
Tag-it HF-I Standard
my-d vp SRF55V10P(Custom)
my-d(a=5)
my-d vp SRF55V10P(ISO)
Parameters for Block Lock (omissible)
lbs:
Block to start locking
(former Ls:)
lbn:
Number of blocks to lock
(former Ln:)
Allows to lock specified blocks (making it read-only).
Specify the block to start locking with "lbs:" and specify the number of blocks to lock with "lbn:".
1 is assigned to "lbn:" if only "lbs:" was specified without specifying "lbn:".
0 is assigned to "lbs:" if only "lbn" was specified without specifying "lbs".
The block will not be locked if 0 was specified to "lbn:" or both of the parameters were omitted.
Note that once locked, the block area becomes read-only and cannot be reset.
In applying lock for my-d, specify 1 for "iso:" and access with ISO-15693 standard.
Multiple Block Locks
Supports locking of multiple blocks, up to 16 positions may be locked, and a parameter error will occur if that number is exceeded.
Blocks should be specified with the following pair of parameters: (,lbs:xxx,lbn:yyy). A parameter error will occur if not specified in
pairs. This option can only be used with the standard format. A parameter error will occur if used with the conventional format.
E.g.:
<RK>2,D40,00000000AAAAAAAA44444444BBBBBBBB88888888,lbs:0,lbn:2,lbs:4,lbn:2,lbs:8,lbn:2
Specifies the block to start writing the data. The 0
omitted. Block is a unit to write to user memory. The following values in the
table are allowed based on the type of inlets. A maximum up to a 3-digit
decimal can be specified, but a parameter error occurs if it exceeds the
maximum amount for the specified inlet. Please see the following table.
Product
Available to specify up to 3 digits in decimals. A parameter error occurs
when it exceeds the maximum for the specified inlet.
Available to specify up to 3 digits in decimals. A parameter error occurs
when it exceeds the maximum for the specified inlet.
338
Capacity of
The number of
1 block.
the overall
blocks.
4bytes
28blocks
4bytes
28blocks
4bytes
40blocks
4bytes
64blocks
4bytes
8blocks
4bytes
8blocks
8bytes
125blocks
4bytes
248blocks
th
block is specified if
Total
capacity.
112bytes
112bytes
160bytes
256bytes
32bytes
32bytes
1000bytes
992bytes