[BLUETOOTH] section
Name of Setting
item
BLUETOOTH
"0": Disable
"1": Enable
PROTOCOL
"0": status3
"1": status4
"2": None
BLUELEVEL
"0": No authentication
"1": Auth. level 2-1
"2": Auth. level 2-2
"3": Auth. level 3
"4": Auth. level 4
PINCODE
0-16 digit characters (except '"')
*Encrypted data
DEVICENAME
0-53 digit characters
ISI
"0", "12" to "1000"( hexadecimal)
ISW
"0", "11" to "1000"( hexadecimal)
PSI
"12" to "1000"( hexadecimal)
PSW
"11" to "1000"( hexadecimal)
BLUEADDRESS
"aabbccddeeff"
BLUEVERSION
"spp3_vX.YY"
CRC
"0": Disabled
"1": Enabled
PAIRING1
"0": Do not remove
"1": Remove
PAIRING2
"0": Do not remove
"1": Remove
PAIRING3
"0": Do not remove
"1": Remove
PAIRING4
"0": Do not remove
"1": Remove
PAIRING5
"0": Do not remove
"1": Remove
PAIRING6
"0": Do not remove
"1": Remove
PAIRING7
"0": Do not remove
"1": Remove
PAIRING8
"0": Do not remove
"1": Remove
PAIRING9
"0": Do not remove
"1": Remove
PAIRING10
"0": Do not remove
"1": Remove
SPP_TIME
"0" to "10"
(Unit:seconds)
LMP_TIME
"0" to "999"
(Unit:0.1 seconds)
PAIRING_INFO1
"aabbccddeeff"
(BD address only)
PAIRING_INFO2
"aabbccddeeff"
(BD address only)
PAIRING_INFO3
"aabbccddeeff"
(BD address only)
PAIRING_INFO4
"aabbccddeeff"
(BD address only)
PAIRING_INFO5
"aabbccddeeff"
(BD address only)
PAIRING_INFO6
"aabbccddeeff"
(BD address only)
Setting value
Default Value
1
1
0
0000
SATO
PRINTER
_
xxxxxxxxx
xxx
800
12
800
12
-
-
0
0
0
0
0
0
0
0
0
0
0
0
100
-
-
-
-
-
-
419
initial
R/W
Contents of Setting item
IB
R/W
Bluetooth
R/W
Communication
protocol (for SBPL)
R/W
Authentication level
R/W
PIN code
R/W
Device name
R/W
ISI
Value will be set to Bluetooth
module after deducting 1 from the
value when odd number is set with
ISI
R/W
ISW
Set ISI≧ISW
R/W
PSI
value will be set to Bluetooth
module after deducting 1 from the
value when odd number is set with
PSI
R/W
PSW
Set ISI≧ISW
-
R
BD address
-
R
Bluetooth firmware version
R/W
CRC mode
-
W
Remove paring
information1 or not
-
W
Remove paring
information2 or not
-
W
Remove paring
information3 or not
-
W
Remove paring
information4 or not
-
W
Remove paring
information5 or not
-
W
Remove paring
information6 or not
-
W
Remove paring
information7 or not
-
W
Remove paring
information8 or not
-
W
Remove paring
information9 or not
-
W
Remove paring
information10 or not
R/W
Time to timeout for disconnection
(SPP layer)
R/W
Time to timeout for disconnection
-
R
Paring information 1
-
R
Paring information 2
-
R
Paring information 3
-
R
Paring information 4
-
R
Paring information 5
-
R
Paring information 6
(LMP layer)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents