9.9 Barcode
9.9

ESC+BG CODE128 Barcode

Code 128 Barcode
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying CODE128 barcode.
[Format]
<BG>aabbbn~n
●Parameter
a [Narrow bar]
b [Height of Barcode]
n [Print data]
[Coding Example]
Narrow bar width: 02, Barcode height: 120, Print data: ABCD123456 (Start character A)
<A>
<V>100<H>200<BG>02120>GABCD123456
<Q>2
<Z>
[Supplementary Explanation]
1. Specify [START CODE] at the head of print data.
(1) START CODE A = [>G]
(2) START CODE B = [>H]
(3) START CODE C = [>I]
2. C/D is an auto-generation.
3. (1) When using "START CODE C", specify print data in even-numbered digit.
(2) When "START CODE C" is set to print data in odd-number digit, specify "START CODE A" or "B" to change the
first one character of print data. And then specify the rest of data with "Code Set Character C" to change it to
even-numbered digit.
e.g.1)
15 digits [123456789012345]
e.g.2)
9 digits / Alphanumeric 6 digits [123456789ABC123]
(3) If using "START CODE C" to specify odd-numbered digit, command error occurs and barcode is not printed.
(4)When start character is omitted, data will be printed with "START CODE B".
BG
Parameter
<42>
<47>
aabbbn~n
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
Valid Range
:
01 ~ 36 dots
=
Valid Range
:
001 ~ 999 dots
=
Barcode data (Refer to the CODE128 - Code Table)
141
ESC+BG
<B>1<C>23456789012345
<C>12345678<B>9ABC123.