[Sample of status reply1](format set to ASCII)
When '4912345678904' and DSFID code 55H, AFI code 10H, and EAS bit 1 are recorded in the RFID tag of ICODE
SLI of "E004010001D9CA2D", UID :.
Command
[DC2]PJ,H1,AS
Status reply [STX]22,02,UD:13,4912345678904[ETX]
Command
[DC2]PJ,H1,H3,AS
Status reply [STX]40,02,UD:13,4912345678904,DS:55,AF:10,EA:01[ETX]
[Sample of status reply 2](format set to HEX)
When '4912345678904' is recorded in the RFID tag of Tag-it HF-I of "E00700002AC1E2BF", UID :.
(Data is not set to the optional flag data.)
Command
[DC2]PJ,H1,HX
Status reply [STX]22,03,ud:13,34393132333435363738393034[ETX]
Command
[DC2]PJ,H1,H2,HX
Status reply [STX]19,03,ud:13,34393132333435363738393034,UI:E00700002AC1E2BF[ETX]
[Sample of status reply 3]
When '4912345678904' and DSFID code 55H, AFI code 10H, and EAS bit 1 are recorded in the RFID tag of ICODE
SLI of "E004010001D9CA2D", UID :.
Command
[DC2]PJ,H2,NO
Status reply [STX]22,02,UI:E004010001D9CA2D[ETX]
Command
[DC2]PJ,H3,NO
Status reply [STX]20,02,DS:55,AF:10,EA:01[ETX] tuika
Command [DC2]PJ,H2,H3,NO
Status reply [STX]40,02,UI:E004010001D9CA2D, DS:55,AF:10,EA:01
USER data
Inlet type (ICODE)
USER data
Inlet type (ICODE)
USER data
Inlet type (Tag-it)
USER data
Inlet type (Tag-it)
UID data
Inlet type (ICODE)
Option flag data
Inlet type (ICODE)
UID data
Inlet type (ICODE)
449
Option flag data
UID data
Option falg data