12.25 System
12.25

ESC+CL Delete CR/LF

Delete CR/LF
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Deletes CR/LF included in print commands.
[Format]
<CL>a
●Parameter
a [Delete CR/LF]
=
[Coding Example]
<A>
<CL>1
<Z>
[Supplementary Explanation]
1. Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with this command for use.
2. This command cannot be used in combination with other commands.
CL
Parameter
<50>
<4D>
a
16
16
The set parameter is maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
0
:
Do not delete CR/LF
1
:
Deletes CR/LF
276