[Format of EPC/TID return data]
"Specify memory"+":"+"Data" +"Line feed(0DH、0AH)"
ee:f...f(,gg:h...h)[CR][LF]
Specifying the memory to be record
[DC2]PA-printer setting IF:RFID setting section parameter
DATA_TO_RECODE : read data depends on RFID data record as below.
"0": BOTH (EPC and TID are returned)
"1": EPC (only EPC is returned)
"2": TID (only TID is returned)
Below is the sample of [DC2]PA setting.
<A>
[DC2]PA,24,IF,18,DATA_TO_RECODE:0[CR][LF]
<Z>
To set the above from settings menu, you can do the same from "Interface"->"RFID"->"Data to Record"
[EPC/TID return data]
Symbol
Parameter name
Memory
e(g...)
f(h...)
Data
Data Example)
EP:E0123456789ABCDEF0123456,ID:E200680612345678
[Return data format (when a command error occurs)]
[NAK]<15>16
[Exception processing]
Parameter name
Identifier
Terminology
Command error
Invalid receive data
Valid range
EP: EPC
ID: TID
Maximum 256 digits
Exception condition
A value outside the range is
specified
Command error
Description
The data received after a command error is determined is not
considered as a parameter of this command.
The data corresponding to Byte 2 and thereafter of the identifier is
ignored.
332
The specified size and received
size are different
Invalid receive data