7.20 Modification
7.20

ESC+AL Field alignment

Field Alignment
ESC
Hexadecimal
code
<1B>
16
Initial value
a=1
When the power switch is OFF
Valid range and
Valid range within items
term of
Valid range between items
command
[Function]
The base reference point specified with print positioning commands <H>, <V> is equal to the "Alignment position" of
this command. The field's base reference points are changeable with "Alignment position". The supported fields are
all text fields, barcode, 2D code, graphics, ruled lines and boxes etc.
[Format]
<AL>a
●Parameter
a
Alignment position =
[Field and alignment positions (in case of font command)]
The number inside the circle indicate the value of parameter a, "Alignment position (the positions specified with print
positioning commands <H>, <V>".
1
BlogÁe
4
7
Field: The area that is rendered with one command
AL
<4B>
<4C>
16
16
1: Top left
2: Top center
3: Top right
4: Middle left
5: Middle center
6: Middle right
7: Bottom left
8: Bottom center
9: Bottom right
2
5
8
For horizontal orientation
39
ESC+AL
Parameter
a
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter becomes initial value at the next item
<A>.
1
3
6
9
4
7
For vertical orientation
2
3
5
6
8
9