Under this condition, if the format of <IP0> EPC code write is applied, it results in the following:
When the standard format is used
<IP0>e:h,enc:c,com:003885,itm:4006606,flt:0,srl:000000000001;
Description of each parameter
e:h,------------- Specifies the standard format
enc:c,------------ Specifies SGTIN96 code conversion
com:003885,-------------- The company prefix is 6 digits
itm:4006606,------------- The item reference is 7 digits 13 digits when combined with com:
flt:0 ----------- The filter value is All Others
srl:000000000001--- Serial number, fixed at 12 digits274877906943 or a smaller number.
;---------------- End terminal
When the one-character parameter identifier in the conventional format is used
<IP0>e:c,c:6,t:7,f:0,d:0038854006606,n:000000000001;
Description of each parameter
e:c,------------ Specifies SGTIN96 code conversion
c:6,-------------- The company prefix is 6 digits
t:7,------------- The item reference is 7 digits 13 digits when combined with c:
f:0,-------------- The filter value is All Others
d:0038854006606, –Number in which the company prefix and item reference are joined together It is 13
n:000000000001--- Serial number, fixed at 12 digits274877906943 or a smaller number.
;---------------- End terminal
When these commands are executed,the above parameters are converted to SGTIN96 code
301803CB4F48B38000000001 and 24 characters, and are written in a tag.