SATO CL4NX Programming Reference Manual page 341

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[Coding example]
<A>
<RU>,01
<IP0>e:h,epc:E0123456789ABCDEF0123456;
<XM>E0123456789ABCDEF0123456
<Z>
[Return status example]
When only the return of TID is specified, the E200680612345678 tag is used in the TID, and [DC2]PK is received
■Write success (TID read success)
[STX]25,1,N,ID:E200680612345678[CR][LF][ETX]
■Write success (TID read failure)
[STX]9,1,T,ID:[CR][LF][ETX]
■Write failure (EPC write failure)
[STX]9,0,E,ID:[CR][LF][ETX]
[Supplemental explanation]
1.The result of writing and EPC/TID is returned when [DC2]PK is received after RFID writing has been performed.
2.Although write is successful status will be returned without data if you fail to read EPC/TID since EPC/TIC read will
be done separately from write.
3.Return data remains the same when EPC code write is specified without print data. Previous value
will be returned.