Poe Enable; Poe Legacy Enable - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

display poe temperature-protection
Syntax
display poe temperature-protection
View
Any view
Parameter
None
Description
Use the display poe temperature-protection command to display the enable/disable status of the
PoE over-temperature protection function on the switch.
Related commands: poe temperature-protection enable.
Example
# Display the enable/disable status of the PoE over-temperature protection function on the switch.
<Sysname>
display poe temperature-protection
The temperature protection is enabled.

poe enable

Syntax
poe enable
undo poe enable
View
Ethernet port view
Parameter
None
Description
Use the poe enable command to enable the PoE feature on a port.
Use the undo poe enable command to disable the PoE feature on a port.
By default, the PoE feature on a port is disabled.
You can use the display poe interface command to display whether PoE is enabled on a port.
Example
# Enable the PoE feature on Ethernet 1/0/3.
<Sysname>
system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Ethernet 1/0/3
[Sysname-Ethernet1/0/3] poe enable

poe legacy enable

Syntax
poe legacy enable
1-5