H3C S3100 Series Command Manual page 1025

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Field
IPv6 is enabled
link-local address
Global unicast address(es)
Joined group address(es)
MTU
ND DAD is enabled, number of
DAD attempts
ND reachable time
ND retransmit interval
Hosts use stateless autoconfig
for addresses
#: View the brief IPv6 information of all interfaces.
<Sysname> display ipv6 interface brief
*down: administratively down
(s): spoofing
Interface
Vlan-interface1
Table 1-5 Description on the fields of the display ipv6 interface brief command
Field
*down: administratively down
(s) : spoofing
Interface
Physical
Protocol
IPv6 Address
IPv6 forwarding state of an interface (after an IPv6 address is configured for
an interface, IPv6 is automatically enabled on it; IPv6 is enabled in the
example)
Link-local address configured on an interface
Aggregatable global unicast address configured on an interface
Address of the multicast group that an interface joins
Maximum transmission unit of an interface
Number of duplicate address detection (DAD) attempts, with DAD enabled
If DAD is enabled, the number of neighbor request messages is also
displayed (configured by using the ipv6 nd dad attempts command)
If DAD is disabled, "ND DAD is disabled" is displayed. (You can set the
number of neighbor request messages for DAD to 0 to disable this
function.)
Neighbor reachable time (which can be configured by using the ipv6 nd nud
reachable-time command)
Interval for retransmitting a neighbor solicitation (NS) message (which can be
configured by using the ipv6 nd ns retrans-timer command)
Hosts use stateless auto-configuration mode to acquire IPv6 addresses
Physical
up
The interface is down, that is, the interface is disabled by using the
shutdown command.
Spoofing attribute of the interface, that is, the link protocol state of the
interface is up, but the link does not exist, or the link is established on
demand, instead of being permanent.
Name of the interface
Interface link state:
*down: Indicates the VLAN interface is administratively down; that is, the
interface is shut down using the shutdown command.
down: Indicates the VLAN interface is administratively up but its physical
state is down; that is, no port in the VLAN is up, which may be caused by
a link failure.
up: Indicates the administrative and physical states of the VLAN interface
are both up.
Link protocol state of an interface
down: Indicates the link layer protocol state of the VLAN interface is
down, generally because no IP address is configured.
up: Indicates the link layer protocol state of the VLAN interface is up.
IPv6 address of the interface (If no address is configured for the interface,
"Unassigned" will be displayed.)
1-9
Description
Protocol
IPv6 Address
up
2008::5600
Description

Advertisement

Table of Contents
loading