Poe Temperature-Protection; Poe Update - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

poe temperature-protection

Syntax
poe temperature-protection enable
undo poe temperature-protection enable
View
System view
Parameter
None
Description
Use the poe temperature-protection enable command to enable PoE over-temperature protection on
the switch.
Use the undo poe temperature-protection enable command to disable PoE over-temperature
protection on the switch.
The PoE over-temperature protection operates as follows:
The switch disables the PoE feature on all ports when its internal temperature exceeds 65°C (149°F) for
self-protect, and restores the PoE feature settings on all its ports when the temperature drops below
60°C (140°F).
By default, PoE over-temperature protection is enabled on the switch.
You can use the display poe temperature-protection command to display whether PoE
over-temperature protection is enabled on the switch.
Example
# Disable PoE over-temperature protection on the switch.
<Sysname>
system-view
System View: return to User View with Ctrl+Z.
[Sysname] undo poe temperature-protection enable
The temperature protection is disabled.

poe update

Syntax
poe update { refresh | full } filename
View
System view
Parameter
refresh: The refresh update mode is used when the PSE processing software is available. The refresh
update mode is to upgrade the original processing software in the PSE.
1-9