display ipv6 nd detection
Syntax
display ipv6 nd detection
View
Any view
Parameters
None
Description
Use the display ipv6 nd detection command to display ND detection configuration.
Refer to the ipv6 nd detection enable command and ipv6 nd detection trust command for related
configuration.
Among S3100 series switches, only S3100-EI series switches support the two commands.
Examples
# Display ND detection configuration.
<Sysname> display ipv6 nd detection
ND detection is enabled in the following VLANs:
2, 10
ND detection trust is configured on the following interfaces:
Interface
Eth1/0/1
Eth1/0/3
Table 1-6 display ipv6 nd detection command output description
ND detection is enabled in the following VLANs:
ND detection trust is configured on the following
interfaces
display ipv6 nd detection statistics
Syntax
display ipv6 nd detection statistics [ interface interface-type interface-number ]
View
Any view
Parameters
interface interface-type interface-number: Displays the statistics of the specified interface.
interface-type interface-number: Specifies the interface type and number
Trusted
yes
yes
Field
The VLAN enabling the ND detection
Lists of ND trust ports
1-10
Description