Table 3-3 Description on the fields of the display device command
SlotNo
SubSNo
PortNum
PCBVer
FPGAVer
CPLDVer
BootRomVer
AddrLM
Type
State
display environment
Syntax
display environment
View
Any view
Parameter
None
Description
Use the display environment command to view the environment temperature of the switch.
Note that only PoE-enabled S3100 series Ethernet switches support this command currently.
Example
# Display the environment temperature of the switch.
<Sysname> display environment
Unit 1:
Slot
0:
Subslot 1:
Subslot 2:
Power
1:
Power
2:
display fan
Syntax
display fan [ unit unit-id [ fan-id ] ]
View
Any view
Field
Normal Temperature
Normal Temperature
Normal Temperature
Normal Temperature
Normal Temperature
Serial number of the slot
Serial number of the sub slot
Number of ports
Version number of the PCB card
Version number of the FPGA encapsulation
Logical version number of the hardware CPLD
Version number of the Boot ROM
MAC address learning mode
Card type
Running state
3-4
Description