History-Record Enable - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

View
HWPing test group view
Parameters
keep-time: Retaining time of the history record for a test group, which is in the range 1 to 1440 in
minutes and defaults to 120 minutes.
Description
Use the history keep-time command to configure the retaining time of the history record for a test
group.
Use the undo history keep-time command to restore the default.
Examples
# Configure the retaining time of the history record for a test group to 240 minutes.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator icmp
[Sysname-hwping-administrator-icmp] history keep-time 240

history-record enable

Syntax
history-record enable
undo history-record enable
View
HWPing test group view
Parameters
None
Description
Use the history-record enable command to enable history record.
Use the undo history-record enable command to disable history record.
By default, history record is disabled. You should configure to save history record as needed.
If you need to save history record, enable it.
If you disable the history record after enabling it, the saved history record will be deleted and the
maximum number of the history record for you to save will not be changed.
If you do not need to save history record, disable it. At this time you can also configure the number
of the history record to be saved, but the history record will not be saved.
Use the display hwping history command to view the history record.
Examples
# Enable history record saving.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator icmp
[Sysname-hwping-administrator-icmp] history-record enable