H3C S3100 Series Command Manual page 1161

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Parameters
None
Description
Use the display oam configuration command to display global Ethernet OAM configuration,
including the periods and thresholds for Ethernet OAM link error event detection.
Related commands: oam errored-symbol period, oam errored-symbol threshold, oam
errored-frame period, oam errored-frame threshold, oam errored-frame-period period, oam
errored-frame-period
errored-frame-seconds threshold.
Examples
# Display global Ethernet OAM configuration.
<Sysname> display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
Table 1-3 display oam configuration command output description
Field
Configuration of the link event
window/threshold
Errored-symbol Event period (in
seconds)
Errored-symbol Event threshold
Errored-frame Event period (in
seconds)
Errored-frame Event threshold
Errored-frame-period Event
period (in ms)
Errored-frame-period Event
threshold
Errored-frame-seconds Event
period (in seconds)
Errored-frame-seconds Event
threshold
threshold,
oam
Detection intervals and triggering thresholds configured for link events
Errored symbol detection interval, which defaults to one second.
Errored symbol event triggering threshold, which defaults to 1.
Errored frame detection interval, which defaults to one second.
Errored frame event triggering threshold, which defaults to 1.
Errored frame period detection interval, which defaults to 1000
milliseconds.
Errored frame period event triggering threshold, which defaults to 1.
Errored frame seconds detection interval, which defaults to 60 seconds.
Errored frame seconds event triggering threshold, which defaults to 1.
1-5
errored-frame-seconds
:
1
:
1
:
1
:
1
:
1000
:
1
:
60
:
1
Description