Stp Compliance - H3C S3100 Series Command Manual

Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

View
System view
Parameters
bridgenum: Network diameter to be set for a switched network. This argument ranges from 2 to 7.
Description
Use the stp bridge-diameter command to set the network diameter of a switched network. The
network diameter of a switched network is represented by the maximum possible number of switches
between any two terminal devices in a switched network.
Use the undo stp bridge-diameter command to restore the network diameter to the default value.
By default, the network diameter is 7.
After you configure the network diameter of a switched network, MSTP adjusts its hello time, forward
delay, and max age settings accordingly. With the network diameter set to the default value 7, the three
time-relate settings, including hello time, forward delay, and max age, are set to their default values as
well.
The stp bridge-diameter command only applies to CIST. It is invalid for MSTIs.
Related commands: stp timer forward-delay, stp timer hello, stp timer max-age.
Examples
# Set the network diameter to 5.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] stp bridge-diameter 5

stp compliance

Syntax
Ethernet port view:
stp compliance { auto | legacy | dot1s }
undo stp compliance
System view:
stp interface interface-list compliance { auto | legacy | dot1s }
undo stp interface interface-list compliance
View
System view, Ethernet port view
Parameters
auto: Configures the port(s) to recognize the MSTP BPDU format automatically and accordingly
determine the format of MSTP BPDUs to send.
legacy: Configures the port(s) to receive and send only compatible-format MSTP BPDUs.
dot1s: Configures the port(s) to receive and send only standard-format (802.1s-compliant) MSTP
BPDUs.
1-16

Advertisement

Table of Contents
loading

Table of Contents