RADIUS scheme view
Parameters
minutes: Wait time before primary server state restoration, ranging from 1 to 255 minutes.
Description
Use the timer quiet command to set the time that the switch waits before it tries to re-communicate with
the primary server and restore the status of the primary server to active.
Use the undo timer quiet command to restore the default wait time.
By default, the switch waits five minutes.
Related commands: display radius scheme.
Examples
# Configure the switch to wait 10 minutes before it tries to restore the status of the primary server to
active.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] radius scheme radius1
New Radius scheme
[Sysname-radius-radius1] timer quiet 10

timer realtime-accounting

Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
View
RADIUS scheme view
Parameters
minutes: Real-time accounting interval, in minutes. It ranges from 3 to 60 and must be a multiple of 3.
Description
Use the timer realtime-accounting command to set the real-time accounting interval.
Use the undo timer realtime-accounting command to restore the default real-time accounting
interval.
By default, this interval is 12 minutes.
Note that:
To control the interval at which users are charged in real time, you can set the real-time accounting
interval. After the setting, the switch periodically sends online users' accounting information to the
RADIUS server at the set interval.
The setting of the real-time accounting interval depends, to some degree, on the performance of
the switch and the RADIUS server. The higher the performance of the switch and the RADIUS
1-63