Nortel Meridian 1 Manual page 76

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

3-20
SL-1 L, LE, and N system upgrades
553-3001-250 Standard 14.00 August 1996
Select the following options in sequence, and insert the B1 disk with
the customer database when you are prompted to do so:
<d>
<a>
<a>
<y>
Follow all screen directions until the database transfer is complete.
Select the following options to quit and reload the system:
<q>
<yes>
<a>
6
After the system initializes, set the ENB/DIS switch to ENB on the
NT6D65 CNI card in Core/Net 0.
7
On the NT9D19 CP card in Core/Net 0, press and release the MAN RST
button. When "SYS700" messages appear on the LCD display, set the
NORM/MAINT switch to NORM. Within 60 seconds, the following
messages will appear on the LCD display:
RUNNING ROM OS
ENTERING CP VOTE
Within 10 minutes, an HWI533 message from the Core/Net 1 CPSI port
indicates the Core 0 memory is shadowed to the Core 1 memory. Wait
until the memory synchronization is complete before continuing.
8
Set the NORM/MAINT switch to NORM on the CP card in Core/Net 1
and perform a redundancy sanity test:
LD 135
STAT CNI
STAT CPU
TEST CPU
TEST CNI c s to test the CNI on the inactive side
Note: Testing the CP and CNI cards may take up to 90 seconds for each
test.
to install the database
to install customer database
to continue with the database installation
to begin the installation
to quit
to confirm quit
to reboot the system
to load the program
to get the status of all configured CNIs
to get the status of both Cores
to test the inactive CP card and CP-to-CP cable