Nortel Meridian 1 Manual page 667

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

9-88
Meridian 1 option 51 upgrades
553-3001-250 Standard 14.00 August 1996
The system automatically performs a sysload during which several
messages will appear on the system terminal.
Verify that the message "SYS702 48" appears on the terminal
during the sysload. (The "48" portion of the message indicates that
the new 48 MB of memory has been located.)
While the sysload is being performed, database conversion occurs.
Verify that the following message appears on the system terminal:
DATA CONVERSION
X11 RELEASE 20.xx TO RELEASE 21.xx
9
Set the date and time:
LD 2
STAD
****
10 Configure networks as CNI groups, based on the number of CNI cards in
the system. Configure the CNI card in slot 12, port 0 for network
group 0. Refer to X11 input/output guide (553-3001-400) for a complete
description of the Configuration Record (LD 17):
Prompt
Response
REQ
CHG
TYPE
CFN
CEQU
YES
EXT0
3PE
_CNI
s p g
EXT1
3PE
_CNI
s p g
to load the overlay
DD MM YY HR MN SC
to exit the program
Comments
Core/Net 0 extended to 3PE
s = card slot (12)
p = port (0)
g = network group (0)
Core/Net 1 extended to 3PE
s = card slot (12)
p = port (0)
g = network group (0)