9-68
Meridian 1 option 51 upgrades
553-3001-250 Standard 14.00 August 1996
Note: Continue with step 5 only if you sent your database to Northern
Telecom for conversion. Otherwise, if you are converting your database
on-site from release 17 or 18, continue with step 6; or, if you are
converting your database on-site from release 19 or later, continue with
step 11.
5
Follow the steps below to install the customer database (converted by
Northern Telecom) on Core 1.
Note: Refer to "Software Installation Tool reference," Software
conversion procedures (553-2001-320).
•
Set the ENB/DIS switch on the NT5D20 IOP/CMDU card to DIS
and remove the card. Install the QMM42 cartridge for release 21
onto the card. Reinstall the card and set the ENB/DIS switch to
ENB.
Note: Wait for 30 seconds until system messages indicate that the
IOP/CMDU card has been successfully enabled, before proceeding to the
next step.
•
To activate the Software Installation Tool, insert disk A1 from the
software upgrade package into the NT5D20 IOP/CMDU in
Core/Net 1.
•
Press the MAN RST button on the NT6D66 CP card in Core/Net 1.
•
Select the following options in sequence, and insert the B1 disk with
the customer database when you are prompted to do so:
<d>
<a>
<a>
<y>
•
Follow all screen directions until the database transfer is complete.
to install the database
to install customer database
to continue with the database installation
to begin the installation