Nortel Meridian 1 Manual page 796

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

12-32
Upgrades to Meridian 1 option 81
553-3001-250 Standard 14.00 August 1996
6
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
When "EDD000" appears on the terminal, perform the data dump. At the
prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
****
7
Test the IOP to IOP SCSI connection and test the CMDUs:
LD 137
TEST SCSI
TEST CMDU to test the hard and floppy disk drives (a floppy
****
8
Clear displays, major alarms, and minor alarms:
CDSP
CMAJ
CMIN ALL
SCPU
CDSP
****
to load the program
to begin the data dump
CAUTION
to exit the program
to load the program
to check the IOP to IOP connection and access to the
CMDUs
diskette must be installed)
to exit the program
to clear the display
to clear all major alarms
to clear all minor alarms
to switch to the other Core
to clear the display
to exit LD 135

Advertisement

Table of Contents
loading