6-18
SL-1 NT system upgrades
553-3001-250 Standard 14.00 August 1996
77 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
78 Set the ENB/DIS switch on the QPC580 CPU Interface card in CPU 0 to
ENB. Verify that the MAINT/NORM switch is set to NORM.
79 In CPU 1, set the MAINT/NORM switch on the QPC580 Interface card
to NORM.
80 Simultaneously press both RLD buttons on the NTND10 CMA cards.
System messages similar to the following will appear:
SYS000
SYSLOAD RLS: xxISSUE:x
DONE
INI000
81 Log into the system.
82 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
Always enter LD 43 from the source (current) media. Do not exit LD 43.
When "EDD000" appears on the terminal, proceed to the next step.
83 Set the ENB/DIS switch on the MSI or EMSI card in CPU 1 to DIS and
remove the card. Replace the QMM42 cartridge for release 19 software
with the QMM42 cartridge for release 21 software. Reinstall and enable
the card.
to begin the data dump
CAUTION
to load the program