Nortel Meridian 1 Manual page 223

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

5-38
SL-1 RT system upgrades
553-3001-250 Standard 14.00 August 1996
16 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
17 Simultaneously press both RLD buttons on the NTND10 CMA cards.
When prompted, remove disk A1 from the A drive and insert disk A2.
System messages similar to the following will appear:
SYS000
INSERT DISK A2 INTO DRIVE A
SYSLOAD RLS: xxISSUE:x
DONE
INI000
18 Immediately following the system initialization sequence, remove
disk A2 from drive A and insert disk A1.
19 Log into the system.
20 Copy the contents of the data disks to the hard disk by entering
LD 43
RES
Insert the additional system disk (A2) when requested. When the restore
sequence is complete, enter
****
21 Remove disk A2 from drive A and insert disk A1.
22 Set the ENB/DIS switch on each MSI or EMSI card to DIS.
to begin the data dump
CAUTION
to load the program
to copy the entire contents of the backup to the hard
disk
to exit the program