Nortel Meridian 1 Manual page 596

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

37 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
38 Press the RLD button on the NTND01 CMA card. When prompted,
remove disk A1 from the A drive and insert disk A2. System messages
similar to the following will appear:
SYS000
INSERT DISK A2 INTO DRIVE A
SYSLOAD RLS: xxISSUE:x
DONE
INI000
39 Immediately following the system initialization sequence, remove
disk A2 from drive A and insert disk A1.
40 Log into the system.
41 Copy the contents of the data disks to the hard disk by entering
LD 43
RES
Insert the additional system disk (A2) when requested. When the restore
sequence is complete, enter
****
42 Remove disk A2 from drive A and insert disk A1.
43 Set the ENB/DIS switch on the MSI or EMSI card to DIS.
Upgrade system installation Upgrading to Meridian 1 system options
Meridian 1 option 51 upgrades
to begin the data dump
CAUTION
to load the program
to copy the entire contents of the backup to the hard
disk
to exit the program
9-17

Advertisement

Table of Contents
loading

Table of Contents