Nortel Meridian 1 Manual page 421

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

7-46
SL-1 XT system upgrade
553-3001-250 Standard 14.00 August 1996
Converting a database from release 15 or 16 to release 21
1
Remove the front and rear covers from the CPU/Network cabinet in the
XT system.
2
Log into the system.
3
Load the Common Equipment Diagnostic Program (LD 35) and check
the status of the CPUs:
LD 35
STAT CPU
Verify that CPU 1 is enabled and CPU 0 is idle. If CPU 0 is enabled, test
and switch the CPUs:
TCPU
SCPU
Check the status of the CPUs again:
STAT CPU
Verify that CPU 1 is enabled and CPU 0 is idle, then enter
****
4
In CPU 1, set the MAINT/NORM switch on the QPC580 CPU Interface
card to MAINT.
5
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
Always enter LD 43 from the source (current) media. Do not exit LD 43.
When "EDD000" appears on the terminal, proceed to the next step.
Note: Your system will have either a QPC584 MSI card or an NT9D34
EMSI card.
6
Set the ENB/DIS switch on the MSI or EMSI cards in CPU 0 and CPU 1
to DIS.
7
Disconnect cables to the faceplates of both MSI or EMSI cards and
remove the cards.
to load the program
to get the CPU status
to test the CPUs
to swap the CPUs
to get the CPU status
to exit the program
to load the program