SL-1 A, M, S, and MS system upgrades
Turning on the power and configuring the system
553-3001-250 Standard 14.00 August 1996
Before you power up the system, review installation steps and verify that all
cards are in the appropriate card slots and properly cabled.
Note: Make sure a terminal is connected to J25 on the I/O panel. Verify
that the terminal is set for 9600 baud, 7 data bits, 1 stop bit, space parity,
full duplex, XON protocol.
1
Perform the appropriate step to restore power in the Core/Network
module:
•
For AC-powered systems, simultaneously set the circuit breaker on
the MPDU in both Core/Network modules to ON (up position).
•
For DC-powered systems, simultaneously set the switch on the
module power supply in both Core/Network modules to ON (up
position).
2
Follow the steps below to install the customer database (converted by
Northern Telecom).
Note: Refer to "Software Installation Tool reference," Software
conversion procedures (553-2001-320).
•
To activate the Software Installation Tool, insert disk 1 from the
software upgrade package into the NT5D20 IOP/CMDU.
•
Press the MAN RST button on the NT9D19 CP card.
•
Select the following options in sequence, and insert the disk with the
customer database when you are prompted to do so:
<d>
<a>
<a>
<y>
•
Follow all screen directions until the database transfer is complete.
•
Select the following options to quit and reload the system:
<q>
<yes>
<a>
to install the database
to install customer database
to continue with the database installation
to begin the installation
to quit
to confirm quit
to reboot the system