Nortel Meridian 1 Manual page 370

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

Follow all screen directions until the software, database, CP-ROM
and IOP-ROM installations are complete.
When the main menu appears, select the following options:
<q>
<yes>
Remove any diskettes from the floppy drive, and type
<a>
When you have rebooted the system, proceed with the next step.
7
Log into the system.
8
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
9
Insert a B1 disk (from the release 21 disk set) titled "DATABASE
BACKUP DISK" into the floppy drive in the IOP/CMDU in Core 1.
10 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed step 12.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
Upgrade system installation Upgrading to Meridian 1 system options
to quit
to confirm quit
to reboot the system
to load the program
to begin the data dump
CAUTION
SL-1 NT system upgrades
6-111