Nortel Meridian 1 Manual page 933

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

10 When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, enter
****
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
11 On the existing system, follow Procedure 1: "Pre-conversion procedure,"
Software conversion procedures (553-2001-320) and print configuration
records. Check the configuration record printouts to identify all
configured I/O ports.
Note: When transferring call processing to a Core module during an
upgrade, one I/O address is required for a CPSI port. If there is no address
available, an SYS 4532 error is displayed. You must make available one
port assignment for a CPSI port.
Upgrade system installation Upgrading to Meridian 1 system options
Upgrades to Meridian 1 option 81
to exit the program
CAUTION
12-169