4-86
SL-1 ST and STE system upgrades
553-3001-250 Standard 14.00 August 1996
20 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
Always enter LD 43 from the source (current) media. Do not exit LD 43.
When "EDD000" appears on the terminal, proceed to the next step.
21 Set the ENB/DIS switch on the QPC742 FDI card to DIS and remove the
card. Replace the QMM42 cartridge for release 10 software with the
QMM42 cartridge for release 15 software. Reinstall and enable the FDI
card.
22 Remove the disks containing release 10 software from the drives and
insert ED floppy disks with release 15 software into the FDU drives.
Insert disk A in drive A and disk B in drive B.
23 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
24 Remove the QPC687 CPU card. Remove the QPC717 ROM card and
replace it with the QPC940 ROM card. Reinstall the CPU Function card.
Carefully align the connector pins when installing a ROM card.
Failure to use care may result in damage to one of the cards or system
failure.
25 Remove the QPC673 Memory card and install the QPC814 Memory
card.
to load the program
to begin the data dump
CAUTION
CAUTION

Advertisement