Nortel Meridian 1 Manual page 887

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

7
Configure the system monitor. Set the switches according to the tables in
Meridian 1 system installation procedures (553-3001-210) with these
exceptions:
For the master, set SW1 positions 1, 2, and 8 to ON.
For slaves, set SW1 positions 1 and 8 to ON.
8
Connect system monitor cables with the following exception in Core 0:
Attach a P0369107 Filter Adapter to the inside of slot J11 on the
right I/O panel.
Connect the narrow ribbon on the NT8D46AD cable from connector
J2 to slot J11 on the right I/O panel.
9
Connect a terminal to the J25 port on the I/O panel in Core 1. Use the
following settings on the terminal:
9600 baud, 7 data bits, 1 stop bit, space parity, full duplex, XON protocol
10 If IPE cards are added in the column(s), cable the lines and trunks.
11 Connect an NT8D80AZ cable from J4 of the 3PE card in Core 0 to J4 of
the 3PE card in Core 1.
12 Connect another NT8D80AZ cable from J3 of the 3PE card in Core 0 to
J3 of the 3PE card in Core 1.
13 In the rear of the Core Modules, remove the I/O panels.
Note: If only Group 0 and Group 1 are equipped, you do not need to
remove the right I/O panel.
14 Remove the eight screws that secure the I/O panels. Keep the screws for
reuse.
Note: You must use the extraction tool to disconnect cables from the
connectors on the rear of the backplane.
15 Using the extraction tool, temporarily disconnect the NT7D90 Ethernet
and NT7D89 RS-232 cables from backplane connector positions 16F and
14D, respectively.
16 Remove the I/O panels but keep them on hand for immediate reuse.
17 In the rear of the Core Modules, install the following cables between
Core 0 and Core 1 (see Figure 12-27).
Upgrade system installation Upgrading to Meridian 1 system options
Upgrades to Meridian 1 option 81
12-123