12-150
Upgrades to Meridian 1 option 81
Table 12-36
Network shelf 0: NTND95AA cable connections to 3PE cards
Network
Cable label
group
0
CPU0-CNI-8D to 3PE-GRP0/0-J3
0
CPU0-CNI-8F to 3PE-GRP0/0-J4
1
CPU0-CNI-9A to 3PE-GRP1/0-J3
1
CPU0-CNI-9C to 3PE-GRP1/0-J4
2
CPU0-CNI-9D to 3PE-GRP2/0-J3
2
CPU0-CNI-9F to 3PE-GRP2/0-J4
3
CPU0-CNI-10A to 3PE-GRP3/0-J3
3
CPU0-CNI-10C to 3PE-GRP3/0-J4
4
CPU0-CNI-10D to 3PE-GRP4/0-J3
4
CPU0-CNI-10F to 3PE-GRP4/0-J4
553-3001-250 Standard 14.00 August 1996
7
Set the ENB/DIS switch to DIS on QPC471 or QPC775 cards.
Leave the ENB/DIS switch on the 3PE cards set to ENB. If the cards
are disabled, the system will initialize.
8
On the QPC441 3PE cards in network shelf 0 of all groups, label and
disconnect the cables connected to QPC215 SBE Cards.
9
As listed in Table 12-36, connect NTND95AA cables to the 3PE
faceplates in network shelf 0 of all equipped network groups.
CAUTION
Connector
Connector
housing
position
Group 0
Group 0
Groups 1 & 2
Groups 1 & 2
Groups 1 & 2
Groups 1 & 2
Groups 3 & 4
Groups 3 & 4
Groups 3 & 4
Groups 3 & 4
3PE
connector
H4
J3
H6
J4
H2
J3
H4
J4
H6
J3
H8
J4
H2
J3
H4
J4
H6
J3
H8
J4