10 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
11 Follow the steps below to convert the database from release 19 or higher
to release 21, and install the customer database on the option 61C
Core/Net 1. You will need the B disk previously created when you
performed a data dump in step 10, or you created when you performed a
data dump at the beginning of this upgrade procedure.
Note: Refer to "Software Installation Tool reference," Software
conversion procedures (553-2001-320).
Set the ENB/DIS switch on the NT5D20 IOP/CMDU card to DIS
and remove the card. Install the QMM42 cartridge for release 21
onto the card. Reinstall the card and set the ENB/DIS switch to
ENB.
Note: Wait for 30 seconds until system messages indicate that the
IOP/CMDU card has been successfully enabled, before proceeding to the
next step.
To activate the Software Installation Tool, insert disk 1 (from the
release 21 disk set) from the software upgrade package into the
NT5D20 IOP/CMDU in Core/Net 1.
Press the MAN RST button on the NT6D66 CP card in Core/Net 1.
Upgrade system installation Upgrading to Meridian 1 system options
Meridian 1 option 51 upgrades
to begin the data dump
CAUTION
9-71

Advertisement

Table of Contents
loading

Table of Contents