17 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
18 Simultaneously press the RLD buttons on both QCA581 CMA cards to
begin a sysload. System messages similar to the following will appear:
SYS000
SYSLOAD RLS: xxISSUE:x
DONE
INI000
19 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
20 Remove the database diskettes from the NTND16 MDU drives on the
RT.
Upgrade system installation Upgrading to Meridian 1 system options
to begin the data dump
CAUTION
to load the program
to begin the data dump
CAUTION
SL-1 RT system upgrades