Load overlay 22 and print the Configuration Record to verify the above
changes:
LD 22
REQ PRT
TYPE CFN
****
After verifying the changes, enter
****
4
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
When "EDD000" appears on the terminal, perform the data dump. At the
prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
5
Set the ENB/DIS switch to ENB on the clock controller card in
Core/Net 0.
6
Set the ENB/DIS switch to ENB on the CNI card in Core/Net 0.
7
Set the ENB/DIS switch to ENB on the clock controller card in
Core/Net 1.
8
Set the ENB/DIS switch to ENB on all of the cards in the network area
of the Core/Network modules in both shelves.