Advertisement

12-48
Upgrades to Meridian 1 option 81

Upgrading CPU 1

553-3001-250 Standard 14.00 August 1996
1
If QPC775 Clock Controller Cards are equipped, perform these steps to
disable the card:
Note: If the system is equipped with QPC471 Clock Controller Cards,
skip this step and proceed with step 2.
LD 60
SSCK 1
SSCK 0
SWCK
DIS CC 1
****
Set the ENB/DIS switch on the clock controller card in CPU 1 to
DIS.
Disconnect the cable from the NT8D36 InterGroup Module at the
junctor board.
Disconnect the cable at the faceplate of the QPC775 card.
If primary or secondary reference cables are equipped, disconnect
them last.
2
Follow the appropriate step below to turn off power to CPU 1:
For AC-powered systems, set the main circuit breaker for the
column (located at the rear of the pedestal) to OFF (down position).
Because of hazardous voltage in AC-powered systems, power to the
entire column must be shut down. This shuts down all functions in the
column including the network group in that column. Relocate essential
services from this group before proceeding.
to load the program
to get the status of clock 1
to get the status of clock 0
if necessary, to switch to clock controller 0
to disable clock controller 1
to exit the program