9-50
Meridian 1 option 51 upgrades
553-3001-250 Standard 14.00 August 1996
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
4
Verify that the ENB/DIS switch is set to ENB on all of the cards in the
network area of the Core/Network module.
5
Press the MAN INT button on the CP card. Watch the initialization
process. Make sure the CNI and 3PE cards are auto-enabled. (The
faceplate LEDs should go out.)
Note: If the network loop corresponding to a CNI port is not enabled, the
LED for that port may not go out.
6
Check for dial tone. If there is no dial tone, do the following:
•
Perform a visual check of the Core/Net module. Verify that each
card is in the correct slot. Verify that all cards are seated, all
ENB/DIS switches are set to ENB, and all red LEDs are off.
•
Verify that all cables are properly and securely connected in the
front and rear of the module.
•
Check the status of the CNI card with LD 135 "STAT CNI" and
ensure that it is software enabled.
•
If the CNI card is software disabled, test the card with LD 135
"TEST CNI c s."
•
If the test is successful, enable the card in LD 135, perform a data
dump with LD 43, and recheck the CNI status in LD 135.
•
Check for dial tone again.
•
If dial tone is still not present, press the MAN INT button on the CP
card. Watch the initialization process. Make sure the CNI and 3PE
cards are auto-enabled. (The faceplate LEDs should go out.)
CAUTION