Nortel Meridian 1 Manual page 629

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

9-50
Meridian 1 option 51 upgrades
553-3001-250 Standard 14.00 August 1996
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
4
Verify that the ENB/DIS switch is set to ENB on all of the cards in the
network area of the Core/Network module.
5
Press the MAN INT button on the CP card. Watch the initialization
process. Make sure the CNI and 3PE cards are auto-enabled. (The
faceplate LEDs should go out.)
Note: If the network loop corresponding to a CNI port is not enabled, the
LED for that port may not go out.
6
Check for dial tone. If there is no dial tone, do the following:
Perform a visual check of the Core/Net module. Verify that each
card is in the correct slot. Verify that all cards are seated, all
ENB/DIS switches are set to ENB, and all red LEDs are off.
Verify that all cables are properly and securely connected in the
front and rear of the module.
Check the status of the CNI card with LD 135 "STAT CNI" and
ensure that it is software enabled.
If the CNI card is software disabled, test the card with LD 135
"TEST CNI c s."
If the test is successful, enable the card in LD 135, perform a data
dump with LD 43, and recheck the CNI status in LD 135.
Check for dial tone again.
If dial tone is still not present, press the MAN INT button on the CP
card. Watch the initialization process. Make sure the CNI and 3PE
cards are auto-enabled. (The faceplate LEDs should go out.)
CAUTION