Nortel Meridian 1 Manual page 393

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

7-18
SL-1 XT system upgrade
553-3001-250 Standard 14.00 August 1996
71 Simultaneously press both RLD buttons on the NTND10 CMA cards.
System messages similar to the following will appear:
SYS000
SYSLOAD RLS: xxISSUE:x
DONE
INI000
72 Log into the system.
73 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
Always enter LD 43 from the source (current) media. Do not exit LD 43.
When "EDD000" appears on the terminal, proceed to the next step.
74 Set the ENB/DIS switch on the MSI or EMSI card in CPU 1 to DIS and
remove the card. Replace the QMM42 cartridge for release 18 software
with the QMM42 cartridge for release 19 software. Reinstall and enable
the card.
75 Set the ENB/DIS switch on the MSI or EMSI card in CPU 0 to DIS and
remove the card. Install the QMM42 cartridge for release 19 software.
Reinstall and enable the card.
76 Remove the disks containing release 18 software from the drives and
insert ED floppy disks with release 19 software into the NTND16 MDU
drives. Insert disk A in DRV A and disk B in DRV B.
77 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
to load the program
to begin the data dump
CAUTION

Advertisement

Table of Contents
loading

Table of Contents