Nortel Meridian 1 Manual page 453

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

8-10
Meridian 1 option 21 upgrades
553-3001-250 Standard 14.00 August 1996
27 Install the NTND02 MSPS card in slot 3.
28 Connect the SDI cable:
Connect the end previously connected to the QPC687 CPU card to
the connector on the NTND02 MSPS faceplate.
Connect the other end of the cable to the I/O panel.
Note: If both SDI ports are configured, connect the input connector of
an NTND37 Dual SDI cable to the SDI cable at the I/O panel. This cable
provides two connectors, one for each port.
29 Set the ENB/DIS switch on the NTND02 MSPS card to ENB.
Before you power up the system, review the installation steps and verify that
all cards are in the appropriate card slots, enabled, and properly cabled. Then
proceed to "Installing option 21 hardware" on page 8-14.