12-182
Upgrades to Meridian 1 option 81
Figure 12-38
Cabling path for network-to-PE connections
Intercabinet
I/O panel
(at rear)
Meridian 1 column
553-3001-250 Standard 14.00 August 1996
Installing network-to-PE cabling and connector housings
There are three cables for each network-to-PE connection (see Figure 12-38):
— Cables from the QPC414 Network Cards in the Network Modules are
routed internally from the faceplate of the cards to the I/O panels in the
rear of the module.
— Cables from the I/O panels are routed externally to connector housings
on the PE cabinets.
— Cables from the connector housings are routed internally to the faceplate
of the QPC659 Dual Loop Peripheral Buffer Card in the PE cabinets.
NT8D73
Cable
QPC414
NT8D86
Network to
I/O Cable
(front)
NT9J96
Intracabinet
Cable
QPC659
PE cabinet
553-5810