15 Check for dial tone. If there is no dial tone (the system is inoperable) and
you cannot afford downtime, switch the loops back to CPU 0 (which still
has the CPU card cage):
Set the ENB/DIS switch on each CNI card on Core 1 to DIS.
Set the ENB/DIS switch on each SBE card on CPU 0 to ENB.
Initialize CPU 0 by pressing the MAN INT button.
Troubleshoot the Core side off-line.
If you can afford downtime, troubleshoot the Core side on-line:
Perform a visual check of the Core Module. Verify that each card is
in the correct slot. Verify that all cards are seated, all ENB/DIS
switches are set to ENB, and all red LEDs are off.
Verify that all cables are properly and securely connected in the
front and rear of the module.
Check the status of the CNI cards with LD 135 "STAT CNI" and
ensure all configured CNIs are software enabled.
If any CNI cards are disabled, enable them in LD 135, perform a data
dump with LD 43, and initialize the system by pressing the MAN
INT button. Otherwise, proceed directly to step 16.
Again, check the status of the CNI cards with LD 135 "STAT CNI"
and ensure all configured CNIs are software enabled.
Check for dial tone again.
16 Following a successful dial tone test, perform the following basic sanity
tests:
Make sure intra-group and inter-group calls can be placed.
Check for error messages, line noise, chatter, or other problems.
Track sources and resolve problems as necessary.
The upgrade of CPU 1 is complete. The system is operating in split-mode
with call processing on Core 1.
Upgrade system installation Upgrading to Meridian 1 system options
Upgrades to Meridian 1 option 81
12-75