SL-1 ST and STE system upgrades
553-3001-250 Standard 14.00 August 1996
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
Defining the option 51C system software
The following steps describe how to define the option 51C software
configuration.
1
Reassign the configuration data from the network loop(s) in the
option 21 to the appropriate loop(s) in the option 51C.
Define the target Controller card using the Configuration Record 2
(LD 97).
Define the network loop(s) using the Configuration Record 2 (LD
97) and Configuration Record (LD 17).
Refer to X11 input/output guide (553-3001-400) for instructions on using
LD 97 and LD 17.
2
Move the network loops using the Move Data Blocks Program (LD 25).
Refer to X11 input/output guide (553-3001-400) for instructions on using
LD 25.
3
Configure the I/O devices to reflect the current configuration (if
required).
4
Reenter customer data blocks (if required). System options and features
must reflect the current configuration.
5
Configure station data blocks (if required).
6
Configure route data blocks (if required).
7
Configure trunk data blocks (if required).
8
Configure remaining system configuration records (if required).
9
Verify system operation before adding new equipment (if required).
10 Configure new equipment and functions, if any.