Nortel Meridian 1 Manual page 511

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

8-68
Meridian 1 option 21 upgrades
553-3001-250 Standard 14.00 August 1996
10 Insert the floppy disks with X11 release 19 software into the disk drives
in the option 21/21E. Insert disk A in drive A and disk B in drive B.
11 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
12 In the option 21E, press the RST button on the NTND02 MSPS card to
begin a sysload. System messages similar to the following will appear:
SYS000
SYSLOAD RLS: xxISSUE:x
DONE
INI000
13 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
14 Remove the database diskettes from the disk drives in the option 21E.
You will complete converting the database to release 21 later in these
procedures after you upgrade the hardware. Proceed to "Installing option 51C
hardware" on page 8-69 to continue with the upgrade.
to begin the data dump
CAUTION
to load the program
to begin the data dump
CAUTION